Pioneers in Remote Therapeutic Monitoring (RTM) Software for Physical Therapists

November 10, 2026

RTM denials cluster. In practice almost all of them trace back to a small number of causes, and none of the common ones are about clinical judgment. They are about counting.

Here are the six that come up most, and what each one actually requires.

The day count does not support the code

Device supply codes turn on days of transmitted data. 98977 requires 16 to 30 days in a 30-day period. 98985 covers 2 to 15 days. They are mutually exclusive.

The denial happens when the code billed does not match what the platform recorded. Sometimes that is a data entry error. More often the biller picked the familiar code out of habit and nobody checked the count.

The fix is mechanical. The day count decides the code, every time, and it should come off a report rather than out of memory.

The time log will not support 20 minutes

98980 requires at least 20 minutes of treatment management in a calendar month. Not approximately twenty. Not usually twenty.

If your documentation says monitoring performed with no minutes, dates or activities attached, you have not supported the code. A reviewer is not obliged to assume the time happened.

Log minutes with the date and what was done. This is the single most common gap I see.

There is no interactive communication documented

Both 98980 and 98979 require at least one interactive communication with the patient or caregiver during the month. Real time, two way.

An app message the patient never opened is not an interactive communication. A voicemail is not an interactive communication.

Document date, mode and who participated. If you called four times and connected once, the one that connected is the one that counts, and that is the one to record.

Billing spans two calendar months

The treatment management codes are tied to the calendar month, not a rolling 30-day window. The device supply codes work on a 30-day period.

Those are different clocks, and a patient whose monitoring period runs from the middle of one month into the next produces claims that look wrong to anyone reviewing them unless your documentation makes the two timeframes explicit.

Map this before go-live rather than after the first rejection.

The device does not meet the definition

The supply codes require software or hardware that meets the FDA definition of a medical device. CMS has confirmed this is a definitional test rather than a requirement for clearance, but the burden of knowing sits with you.

A general home exercise app is not automatically an RTM device. If you cannot explain in one sentence how your platform meets the definition, ask your vendor and get the answer in writing.

This one is worse than a denial. It is a repayment exposure across every claim you have submitted.

The device supply code was billed too soon

There must be a minimum gap between device supply submissions for the same patient. Bill the next cycle early and it denies.

This is usually a workflow problem rather than a knowledge problem. It happens when billing runs on a fixed calendar day instead of on the patient’s actual cycle.

What to do with this

Pull ten RTM claims from last quarter, including at least three that were denied. For each one, find the day count, the minute log, and the interactive communication. If you cannot find all three in under a minute, a reviewer will not find them either.

That exercise usually tells you which of the six is your pattern. Most practices have one dominant failure mode rather than six scattered ones, and fixing the dominant one moves the number.

What this means for your clinic

None of these require clinical change. They require the counting to be automatic and the documentation to be in one place.

If your platform does not produce a report showing day counts, cumulative minutes and interactive communications per patient per period, you are doing this manually, and manual is where denials come from.

If you want to see what an audit-ready export looks like, request a demo and ask us to show you one before anything else. Our RTM CPT codes guide has the full requirement detail for each code. You can also run your own numbers in the RTM calculator.